42 Month Warranty
| Description | Super Charged HF00-SQPROAL700 | |||||||
|---|---|---|---|---|---|---|---|---|
| Output Voltage at No Load | 235V ± 15V AC | |||||||
| Output Frequency | 50Hz ± 1Hz | |||||||
| Output Wave Form | Square Wave | |||||||
| Nominal Battery Voltage | 12V DC | |||||||
| Battery Low Cut Off | 10.5V ± 0.2V DC | |||||||
| Inverter Dimension | 330X300X168 | |||||||
| Inverter Weight | 8 kgs | |||||||
Charging Mode
| Description | Shaurya 12V 625 VA | Shaurya 12V 825 VA | Shaurya 12V 1050 VA | Shaurya 24V 1500 VA | 
|---|---|---|---|---|
| Maximum Charging | 9.5Amp ± 1.5Amp | 10Amp ± 1.5Amp | 12.5Amp ± 1.5Amp | 12.5Amp ± 1.5Amp | 
| Current (NC) | ||||
| Maximum Charging | 13Amp ± 1.5Amp | 14Amp ± 1.5Amp | 17Amp ± 1.5Amp | 17Amp ± 1.5Amp | 
| Current (HC) | ||||
| Boost Charging Voltage | 14.4V ± 0.2V DC | 28.8V ± 0.4V DC | ||
| Tickle Charging Voltage | 13.7V ± 0.2V DC | 27.4V ± 0.4V DC | ||
| Charging Current at 120V Mains Input | 8 - 10 Amp Charging Current* (*Depends Upon Battery Voltage) | |||
| Change Over Time Mains to Back-Up (@ UPS Mode) | ≤ 10 msec | |||
| Change Over Time Back-up to Mains (@ UPS Mode) | ≤ 10 msec | |||
| Change Over Time Mains to Back-up (@ Normal Mode) | ≤ 40 msec | |||
| Change Over Time Back-up to Mains (@ Normal Mode) | ≤ 10 msec | |||
| Input Voltage Range(@ Normal Mode) | 90V - 300V ± 10V AC | |||